FERKL · Building materials · Ytong
Ytong · Calculate quantities
Autoclaved aerated concrete masonry, complementary components, mortars, fixings and tools. The application depends on the selected variant.

We currently deliver Ytong, Silka and Multipor within Austria. Availability, actual freight costs and timing are confirmed in your individual quotation. Non-binding estimate.
ytong · Project
Calculate quantities
SAP 10012372
Surface 1
Add matching mortar
Published areas per pallet may be rounded. The calculator rounds up using the required piece count and stated pieces per packaging unit; area figures remain approximate.
Technical data and footnotes · SAP 10012372
Aerated concrete blocks for highly insulating external walls of single-leaf construction.
- Compressive-strength / bulk-density class
- PV 2-0.35
- Design thermal conductivity of masonry λdesign,mas
- 0.080 W/(mK)
- U-value of the unplastered external wall
- 0.26 W/(m²K)
- Fire resistance of the specified construction
- REI-M 90
- Wall build-up with thin-coat render: U / Rw
- 0.25 W/(m²K) / 42.5 dB
- Wall build-up with base render: U / Rw
- 0.25 W/(m²K) / 44.3 dB
- Wall build-up with insulating render: U / Rw
- 0.23 W/(m²K) / 43.2 dB
- Indicative maximum parapet masonry height
- 75 cm; depends on bonded area and structural stability verification; follow the installation instructions
- Unit
- pallet
- Pieces per pallet
- 30
- Approximate area per pallet (m²)
- 4.5
- Minimum quantity
- 1 pallet
- Mortar requirement (kg/m²)
- 3.6
- Matching mortar: SAP number
- 10011000
- Pieces required per square metre
- 6.67
- Application stage
- Laying masonry
- Use Ytong FIX N200 for installation.
- Dimension order: length × thickness × height.
- Consumption and pallet areas are indicative. Order quantities depend on the selected variant and its packaging.
- Load capacity, fire resistance and thermal performance apply only to the specified wall build-up and installation conditions. Project-specific verification is required separately.
- Tongue-and-groove joints with handholds on the ends.
- U-values for unplastered external walls include a surface thermal resistance of 0.17 m²K/W.
- Thermal base course: lay on the levelling layer with FIX N200. Mean compressive strength: 2.5 N/mm².
- Parapet: maximum unfinished height is indicative and depends on the bonded area on the slab. Follow the stability verification and installation instructions. REI 90 applies to the described build-up.
- Thin-render build-up: 15 mm internal plaster; outside, 8 mm base and finish coating. Base-render build-up: 15 mm internal plaster; outside, 20 mm lightweight base render, 3 mm bonding mortar and 2 mm silicate coating. Insulating-render build-up: 15 mm internal plaster; outside, 40 mm insulating render and 5 mm base and finish coating.